WEBVTT

00:00:00.000 --> 00:00:07.000
 Welcome to our customer reference video about the use of lipasanF® at the Amperverband in Munich.

00:00:07.000 --> 00:00:17.000
 The affected plant is located in Geisel-Bullach and cleans the wastewater from around 10 municipalities with 250,000 inhabitants.

00:00:17.000 --> 00:00:20.000
 Exit situation

00:00:20.000 --> 00:00:28.000
 The plant collects the grease from the public channel system via the ventilated sand and grease catch.

00:00:28.000 --> 00:00:37.000
 The daily use of this grease is moistened and sealed in an external collection tank of about 30 cubic meters.

00:00:37.000 --> 00:00:45.000
 Every three to four months, the collection tank is excavated, cleaned and the grease is externally disposed of.

00:00:45.000 --> 00:00:54.000
 By using lipasanF®, a result improvement of about 20,000 euros per cleaning process is achieved.

00:00:54.000 --> 00:00:56.000
 Test setup

00:00:56.000 --> 00:01:07.000
 After the analysis of the collected grease sample on site, the collection tank was equipped with an air lance to secure the ventilation and through mixing of the grease.

00:01:07.000 --> 00:01:12.000
 The air lance is connected via the sand and grease catch.

00:01:12.000 --> 00:01:19.000
 Due to the high amount of grease, in this case we decided to use an IBC for the dosage.

00:01:19.000 --> 00:01:28.000
 Here, 10 liters of lipasanF® with 200 liters of water are mixed in a temperature range of 25 to 30 degrees Celsius

00:01:28.000 --> 00:01:33.000
 and then dosed into the grease collection tank via a drain hose.

00:01:33.000 --> 00:01:35.000
 Test run

00:01:35.000 --> 00:01:41.000
 The existing grease has already been collected for four months and would have been excavated in the short term.

00:01:41.000 --> 00:01:44.000
 This recording shows the starting situation.

00:01:44.000 --> 00:01:51.000
 After 24 hours, you can already see a significant change in the consistency of the grease.

00:01:51.000 --> 00:02:02.000
 Already after 48 hours, the consistency was partly so liquid that a part was pumped into an intermediate shaft and then transferred to the v-tower.

00:02:02.000 --> 00:02:08.000
 Of course, fresh grease from the grease and sand catch was also added every day.

00:02:08.000 --> 00:02:10.000
 Result

00:02:10.000 --> 00:02:18.000
 Here the preliminary result after three weeks of dosage of lipasanF®.

00:02:18.000 --> 00:02:30.000
 After the complete emptying of the grease collection tank in the v-tower, this no longer shows any grease adhesion.

00:02:30.000 --> 00:02:37.000
 After that, no further cleaning measures are necessary.

00:02:37.000 --> 00:02:40.000
 Ecology

00:02:40.000 --> 00:02:46.000
 Ecologically, grease is used optimally as an energy carrier and biogas is gained.

00:02:46.000 --> 00:02:54.000
 Economically, there is a result improvement of 20,000 euros through grease separation and subsequent biogas extraction.
